OP32 – Installation manual
31
7.3 ORI Receiver with integrated interface
Power supply:
Nominal 24Vdc
Instantaneous minimum voltage: 12V
Instantaneous maximum voltage: 30V
Reception distance:
See chapter “Transmission Lobes”
Current consumption
50 mA in reception
100 mA when switching outputs
250 mA average probe activation/deactivation period (max 250 mA)
Signal interpretation:
Compatible with OP32 and selective activation transmitters (E.g. E83MC, E83WA,
E83TXL)
Weight:
85 g
Protection class:
IP68 front
IP54 rear
Dimensions:
68mm x 38.5mm x 29.5mm
Connections:
ODU GKL0C-P10RC00-0000 connector
10m extension for ORI P/N: 6739899107
25m extension for ORI P/N: 6739899113
Input Signals:
15 - 30V, 1,5mA max opto-isolated inputs for activating/deactivating and channel selection.
Output Signals:
Unpolarised 48V 20mA solid-state relay contacts, with electronic overload and short
circuit protection.
I/O Signals:
INPUTS
The functions of the connections are as follows:
START Activate transmission
SELECT – Select probe
OUTPUT
The polarity of the signals is referred to the same terminal
PROBE Touch signal
LOW BATTERY
ERROR
SSR with common contact