marposs TESTAR E4N Specifications

General IconGeneral
Brandmarposs
ModelTESTAR E4N
CategoryMeasuring Instruments
LanguageEnglish

Summary

INTRODUCTION

DESCRIPTION

Overview of the E4N column, its features, and connectivity options.

FRONT AND REAR VIEWS

Visual representation and identification of the column's front and rear panels.

TECHNICAL SPECIFICATIONS

Detailed electrical, environmental, and physical specifications of the E4N column.

OVERALL DIMENSIONS

Dimensions and physical layout of the E4N column for installation planning.

INSTALLATION AND USE

MECHANICAL INSTALLATION

Steps and considerations for physically mounting the E4N column units.

CONNECTION OF A COLUMN TO THE MAINS POWER SUPPLY

Procedure for connecting the E4N column to the electrical power source.

CONNECTIONS TO THE MAINS POWER SUPPLY OF A GROUPS OF E4 N COLUMN

Method for powering multiple E4N columns connected in series.

CONNECTION TO THE MAINS COMPRESSED AIR SUPPLY

Requirements and procedure for connecting air supply for air/electronic modules.

CONNECTING TRANSDUCERS

Steps for physically connecting sensor transducers to the E4N column.

E4 N COLUMN SELF TESTS AND IDENTIFICATION

How the E4N column performs self-tests and identifies its version/data upon startup.

HOW TO PROGRAM THE E4 N COLUMN

PROGRAMMING TYPES

Overview of different measurement tasks and corresponding programming modes.

GENERAL EDITING RULES

Fundamental rules for navigating menus and editing parameters within the E4N column.

USING THE KEYS

Explanation of the keypad functions and navigation within the programming interface.

ENTERING AND EXITING THE PROGRAMMING MODE

Step-by-step guide to accessing and leaving the E4N column's programming menu.

SELECTING THE PROGRAMMING LANGUAGE

Process for changing the display language for menus and messages.

DEFAULT PROGRAMMING VALUES

Information on the pre-programmed default settings for various measurement tasks.

PROGRAM: MENU

Description of the main programming menu with options for channel configurations.

MEASURE: MENU

Details on programming basic measurement variables like tolerance and scale.

ADVANC.: MENU

Configuration of advanced variables including language, communication, and display.

HOW TO RESTORE THE DEFAULT VALUES

Procedure to reset the E4N column to its factory default programming.

M.SYST= (System of measurement)

Sets the measurement unit system (e.g., metric, inch) for display.

TOLER += (Upper tolerance limit)

Defines the acceptable upper limit for a measurement.

K.CH.A= (Multiplication coefficient for the channel A signal)

Sets the scaling factor for the signal from channel A.

LANGUAG= (Language)

Selects the display language for the E4N column interface.

M.TYPE= (Type of measurement: Static;Dynamic)

Configures the column for static or dynamic measurement modes.

COMMUT= (Commutation mode)

Sets the mode for switching between multiple measurements or sensors.

PROGRAMMING EXAMPLES FOR THE E4 N COLUMN

HOW TO PROGRAM A MEASUREMENT FORMULA

Guide to defining measurement formulas using sensor signal coefficients (K values).

MEASURING AN OUTER DIAMETER WITH ONE SENSOR

Practical example of programming the E4N for single-sensor outer diameter measurement.

MEASURING AN INNER DIAMETER AND AN OUTER DIAMETER WITH TWO SENSORS

Example demonstrating programming for measuring both inner and outer diameters simultaneously.

GAP MEASUREMENT WITH TWO SENSORS

Configuration example for measuring the gap between two components using two sensors.

TAPER MEASUREMENT WITH FOUR TRANSDUCERS

Example illustrating how to program for taper measurement using four transducers.

ADJUSTMENT PROCEDURE

ADJUSTING LVDT, HBT AND MRT SENSORS

Step-by-step guide for mechanically and electronically adjusting inductive, HBT, and MRT sensors.

ADJUSTING AIR;ELECTRONIC SENSORS

Procedure for adjusting air/electronic sensors using master gauges and control knobs.

FUNCTION OF THE TWO ADJUSTERS ON THE AIR;ELECTRONIC MODULE

Explanation of the roles of the sensitivity and zero adjusters on the air/electronic module.

CALIBRATION PROCEDURE

CALIBRATION OF ONE OR MORE MEASUREMENTS, EACH WITH ONE MASTER

Process for calibrating measurements using a single master gauge.

CALIBRATION OF ONE OR MORE MEASUREMENTS, EACH WITH TWO MASTERS

Procedure for calibrating measurements when using two master gauges.

AMPLIFIER MODULES

AMPLIFIER MODULE FOR LVDT SENSORS

Details on the amplifier module for connecting LVDT sensors, including pinouts and versions.

AMPLIFIER MODULE FOR HBT SENSORS

Information on the amplifier module for HBT sensors, covering connectors and signal pins.

AMPLIFIER MODULE FOR MRT SENSORS

Description of the amplifier module compatible with MRT sensors, including its pin configuration.

AMPLIFIER MODULE FOR AIR;ELECTRONIC SENSORS

Overview of the amplifier module designed for air/electronic sensors, including connector types.

CONNECTION TO EXTERNAL DEVICES

CONNECTION TO AN EXTERNAL PUSHBUTTON BOX OR A FOOTSWITCH

General guide for connecting external control devices like pushbutton boxes and footswitches.

EXTERNAL PUSHBUTTON BOX

Details on the four-button external pushbutton box and its functions in static/dynamic modes.

FOOTSWITCH

Information on connecting and using an external footswitch for controlling the E4N column.

CONNECTING EXTERNAL DEVICES TO A GROUP OF COLUMNS

Method for connecting external devices to a system of multiple E4N columns.

INTERFACES

DIGIMATIC INTERFACE

Description of the Digimatic serial interface for data transfer to analyzers or concentrators.

ANALOG OUTPUT INTERFACE

Information on the analog output interface for transferring measurement values to statistical analyzers or recorders.

RS232 INTERFACE

Details on the RS232 interface for serial printer or PC connections, including protocol customization.

PRINT MODE

Configuration and usage of the print mode for transmitting measurement data via RS232.

PROGRAMMING ERROR MESSAGES AND SOLUTIONS

ACCESSORIES AND SPARE PARTS

SPARE PARTS AND POWER SUPPLY CABLES

List of available spare parts, power supply cables, and their part numbers.

ACCESSORIES

General category for additional accessories and cables for the E4N column.

CABLES

List of various cables for connecting different modules and devices to the E4N column.

PUSHBUTTON BOX AND FOOTSWITCH

Specific accessories including pushbutton boxes and footswitches for remote control.

ACCESSORIES FOR E4 N AIR COLUMN

Specialized accessories designed for the E4N column's air/electronic modules.

MANUALS

List of available user and programming manuals for the E4N column in different languages.