EasyManua.ls Logo

MARTINDALE ET4500 - 9.7 Voltage, frequency, and phase rotation; Phase Rotation Specifications; Voltage Measurement Specifications; Frequency Measurement Specifications

Default Icon
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Martindale ET4000 / ET4500 Technical specifications
76
9.7 Voltage, frequency, and phase rotation
9.7.1 Phase rotation
Nominal system voltage range ......... 100 V
AC
- 550 V
AC
Nominal frequency range .................. 15 Hz - 500 Hz
Result displayed ............................... 1.2.3 or 3.2.1
9.7.2 Voltage
Measuring range (V) Resolution (V) Accuracy
0 - 550 1
(2 % of reading + 2 digits)
Result type ........................................ True r.m.s. (trms)
Nominal frequency range .................. 0 Hz, 15 Hz - 500 Hz
9.7.3 Frequency
Measuring range (Hz) Resolution (Hz) Accuracy
5.00 - 9.99 0.01
(0.2 % of reading + 1 digit)
10.0 - 499.9 0.1
Nominal voltage range ...................... 20 V - 550 V
9.7.4 Online terminal voltage monitor
Measuring range (V) Resolution (V) Accuracy
10 - 550 1
(2 % of reading + 2 digits)