OPERATOR’S
M ANUAL
Signal Extraction
Pulse CO-Oximeter
Masimo Rainbow
®
SET
®

Table of Contents

Questions and Answers

  • J
    James SmithSep 9, 2025
    Why is my Masimo SET Medical Equipment making a continuous speaker tone?
    • K
      kreidSep 9, 2025
      If your Masimo SET Medical Equipment is making a continuous speaker tone, it indicates an internal failure and the instrument requires service. Press the Alarm Silence button to silence the alarm. If the alarm continues to sound, power down the Instrument and remove the Handheld battery if necessary.
  • T
    Tyler YoderSep 12, 2025
    What causes unexpectedly high SpCO readings on Masimo SET Medical Equipment?
    • C
      Corey DunnSep 12, 2025
      An unexpectedly high SpCO reading on the Masimo SET Medical Equipment can be caused by a possible elevated methemoglobin level. Submit a blood sample for laboratory CO-Oximetry test.
  • B
    bbennettSep 14, 2025
    How to resolve difficulty or no SpO2/SPCO*/ SPMET* reading on Masimo SET Medical Equipment?
    • T
      Theresa KingSep 14, 2025
      To resolve difficulty or no SpO2/SPCO*/ SPMET* reading on Masimo SET Medical Equipment, verify the docking station power cord is plugged in and the docking station power indicator light is illuminated. Verify/set the 50/60hz menu setting. Verify proper sensor and sensor size for the patient. Shield the sensor from excessive or strobing light.
  • D
    Daniel SteeleSep 16, 2025
    How to resolve difficulty or no SpCO/SpMet reading on Masimo SET Medical Equipment?
    • J
      Jeff CarpenterSep 16, 2025
      To resolve difficulty or no SpCO/SpMet reading on Masimo SET Medical Equipment, minimize or eliminate motion at the monitoring site. Verify the use of an SpCO/SpMet capable sensor and the proper sensor size for the patient.

Summary

Safety Information, Warnings and Cautions

General Precautions and Contraindications

Covers contraindications and initial warnings/cautions for the Rad-57 device.

Operational Hazards and Safety

Details hazards like explosion, electric shock, light interference, and patient safety protocols.

Instrument Handling and Environmental Factors

Addresses handling, moisture, liquids, modifications, and environmental factors affecting the instrument.

Interference and Electrical Safety

Discusses EMI, FCC compliance, electrical shock prevention, and battery safety measures.

SECTION 1 - OVERVIEW

SECTION 2 - SYSTEM DESCRIPTION

Rad-57 Front Panel Controls

Identifies and describes the controls and indicators on the front panel of the Rad-57.

Rad-57 Rear Panel and Battery Installation

Details the rear panel components and the procedure for installing batteries.

SECTION 3 - SETUP

Initial Monitor Setup

Guides through the initial setup process, including battery installation and frequency configuration.

SECTION 4 - OPERATION

Basic Operation and Setup

Outlines the general setup and initial steps for operating the Rad-57.

Successful Monitoring and Sensor Use

Provides practices for successful SpO2 monitoring and proper sensor application.

Sensitivity Settings and Actions

Explains sensitivity settings and actions for different monitoring conditions.

Battery Status and Alarms

Details battery level indicators and low battery audible alarm behavior.

Front Panel Controls and Menu Navigation

Describes front panel controls and menu navigation procedures.

Setup Menu Levels 1 & 2

Covers alarm volume, silence, and alarm limit settings.

SECTION 5 - ALARMS AND MESSAGES

Alarm Indication and Limits

Describes how alarms are indicated and the configurable alarm limits.

SECTION 6 - TROUBLESHOOTING

General Troubleshooting

Provides a chart for common problems like no power, speaker issues, and button failures.

Measurement and Reading Troubleshooting

Addresses issues with SpO2 correlation, unexpected readings, and no readings.

SECTION 8 - SENSORS AND PATIENT CABLES

SECTION 9 - SERVICE AND MAINTENANCE

Masimo SET Rainbow SET Rad-57 Specifications

General IconGeneral
BrandMasimo SET
ModelRainbow SET Rad-57
CategoryMedical Equipment
LanguageEnglish

Related product manuals