Section 2 - Installation
Rev. 2.0 04/16 6 H6630EM-LIT
2-2 Control Wiring
Motor Cable
Encoder Cable
CAUTION
Verify proper alignment of plug when connecting to motor or encoder
connection. DO NOT FORCE, as the pins may become damaged.
Motor and
Encoder cables must be run in separate conduits and be separated within the
enclosure.
Route and terminate the H5535-FDBK-20M (encoder cable) and H5535-PWR-20M (motor cable) or
H5535-PWRBRK-20M (motor cable with brake) to the control panel terminal points per the H4803
series drawing. Connect the cables to the encoder and motor with the screw on connectors.
Refer to the applicable H6630EM electrical drawings for termination points of all devices including the
panel end of the motor and encoder cables (see Appendix A).
Terminal points are provided to wire in an external LRR (line run relay) contact which enables and
disables automatic control. The LRR contact should close when the process line starts. A jumper is
installed to bypass the line run relay contact and requires removal if an external contact is used. Refer
to the specific H4803 series drawing supplied with the system or to the appendix in this H6630EM
manual. If a customer LRR is not used, do not remove the jumper in the control panel.
The panel is equipped with a Stop button/function. If you wish to tie the controller into a global E-Stop
circuit, provisions have been provided in the panel. See electrical schematics for wiring instructions.