Section 3 HMI (Human Machine Interface) Displays
Rev. 2.0 04/16 16 H6630EM-LIT
Local/Remote -
Selects whether control of the drive is Locally or Remotely
controlled over the network.
Maintenance Screen Status
Status indicators on the “Maintenance Screen” are useful to service personnel and not needed in a day-
to-day operation.
System health is represented here by means of heartbeat, drive temperature in Celsius and drive
status (as displayed on the “Main Screen”). When a trip occurs, a specific trip condition phrase or
number may be displayed that can be looked up in the troubleshooting section.
Motor RPM and Motor Current Amps are instantaneous readouts for motor speed and current draw.
Analog Inputs 1-3 can vary depending on application, but generally represent the detector, feedback
transducer and remote offset station inputs. All three are not always used and depend on what types of
sensors are wired to the respective terminals. See the wiring diagram.
Detector Zero Value is the value captured when the “Detector Zero” button is pressed. Detector Error
is different between current strip position and Detector Zero Value.
Percent Load is a real time display as a % of the current load on the actuator motor. Use this when
setting “Load Limit”.