11921 Slauson Ave.  Santa Fe Springs, CA.  90670  (800) 227-4116  FAX (888) 771-7713
38
STEP 7 - INSTALL CONTROL SWITCH - Continued
2. Insert control switch wir-
ing into the 3/4” hole on the 
corner post and run it under 
the vehicle body to the pump 
assembly. (See dashed line 
- FIG. 38-1.) Insert switch 
wiring through cord grip on 
pump mounting plate (FIG. 
38-2). Connect the switch 
wiring to the pump assembly 
as shown in (FIG. 38-2).  
3. Push control switch and ca-
ble back into the ¾” hole in 
the vertical post until con-
trol switch cover touches 
the post (FIG. 38-1). Attach 
control switch to vertical 
post with 2 self-tapping 
screws (FIG. 38-1).
ROUTING CONTROL SWITCH WIRING 
FIG. 38-1
3/4” HOLE
(2 PLACES)
VEHICLE BODY 
VERTICAL POST
CONTROL SWITCH 
WIRING
CONTROL SWITCH
SELF-TAPPING 
SCREW, 1-1/2” LG. 
(2 PLACES)
4. If necessary, use clamps 
and self-tapping screws, 
from installation parts 
bag, to secure switch 
cable to vehicle (FIG. 
38-1). 
CONTROL SWITCH WIRING CONNECTIONS 
FIG. 38-2
SOLENOID SWITCH
POWER DOWN MODULE
WHITE WIRE
GREEN WIRE
CORD GRIP
WHITE WIRE 
TO TERMINAL 1 
BLACK WIRE 
TO TERMINAL 2 
FUSE HOLDER
ASSEMBLY