SYSTEM DIAGRAMS
TABLE 78-1
Solenoid Switch  12V 24V
Coil Resistance: 5.4Ω @70ºF, ±15% 20.1Ω @70ºF, ±15%
Ampere: 2.2A 1.2A
Coil terminal torque: 10-15 lb-in max.
Contact terminal torque: 30-35 lb-in max.
Solenoid Valves (S1 & S2)
S1 Coil Resistance: 6.6Ω @ 70ºF, ±15% 26.7Ω @ 70ºF, ±15%
S1 Ampere: 1.8A 0.9A
S2 Coil Resistance: 7.5Ω @ 70ºF, ±15% 30.8Ω @ 70ºF, ±15%
S2 Ampere: 1.6A 0.78A
Coil terminal torque: 15-45 lb-in max.
Valve cartridge torque: 25-30 lb-ft max.
Coil nut torque: 15-45 lb-in
Digital Cycle Counter
Operating Voltage: 7V - 30 VDC
Ampere: <2mA
Solenoid Lock Valve
Coil Resistance: 8.0Ω @ 70ºF, ±15% 30Ω @ 70ºF, ±15%
Ampere: 1.5A 0.8A
Coil nut torque: 3-4.5 lb-ft max.
Valve cartridge torque: 18.5-22 lb-ft max.
Ground Cable 
Cap Screw Torque: 24 lb-ft max.