138
Rewinder RW500
Decommissioning, storage
Storage
Shutting down
the machine
Here's how to shut down the machine:
Remove products, tools from the machine.
Clean and maintain machine.
See chapter "10 Instandhaltung".
The machine is temporarily shut down.
10.2.2 Final decommissioning
Proceed as follows to shut the machine down permanently.
Prerequisites These prerequisites must be fulfilled:
• Main switch is switched off.
• Electrical supply is disconnected.
• Compressed air supply is disconnected.
Shutting down
the machine
permanently
Here's how to shut down the machine permanently:
Remove products, tools from the machine.
Dismantle the machine by following the installation steps in the oppo-
site sequence.
For transport, observe the instructions in Chapter "6 Transport and
interim storage".
The machine is permanently shut down.
10.3 Storage
Proceed as follows to store the machine.
Prerequisites These prerequisites must be fulfilled:
• Machine is shut down.
Storing the machine Here's how to store the machine:
Check the premises with respect to the temperature and humidity.
See chapter "3.2.8 Ambient conditions".
The higher the humidity, the greater the danger of corrosion.
For long-term storage, measures for corrosion protection must be tak-
en.
Observe the specifications regarding the weight and size of the ma-
chine when selecting the premises.
See chapter "3.2 Technical data"
Use a suitable fork lift for transport.
See chapter "3.2.5 Shipping and transport data".
Cover the machine with foil.
The machine is stored.
After a temporary shutdown, the machine must be commissioned again.
See chapter "7 Installation, commissioning".