EasyManua.ls Logo

Medivators DSD-201 - Service Manual

Medivators DSD-201
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ac)
#
/00
POST
DSD™-201
Endoscope
Reprocessor
ervice
Manual
Software
Version
3.xx
0050
Listed
MM03-0047
Revision
D

Other manuals for Medivators DSD-201

Question and Answer IconNeed help?

Do you have a question about the Medivators DSD-201 and is the answer not in the manual?

Summary

INTRODUCTION

Manual Usage Guide

Explains how to use the manual, notes, cautions, and warnings.

General Safety Guidelines

Outlines general safety guidelines, intended use, and operator precautions.

General Operational Guidelines

Covers installation, maintenance, water quality, detergent, disinfectant, and precleaning procedures.

INSTALLATION

Installation General Procedures

Instructions for moving the reprocessor and ensuring the reservoir cover is in place.

System Supply Requirements

Details water, electrical, air, and drain system requirements for proper operation.

Installation Verification Procedure

Outlines the procedure for performing a trial run and checks to verify correct installation.

OPERATOR CONTROLS

Operator Controls Overview

Overview of operator controls and how to set up and program the reprocessor.

Control Panel Components

Describes the reprocessor's control panel interface and components.

LED Indicator Functions

Explains the function and types of LED indicators used for system status and errors.

LCD Screen Operations

Details how the LCD screen displays messages, prompts, and program status.

Numeric Keypad Functionality

Explains the use of the numeric keypad for entering information and navigation.

Function Key Operations

Details the purpose and operation of each function key on the control panel.

OPERATION

Operation Section Introduction

Explains startup, shutdown, programming, leak testing, and endoscope preparation.

Reprocessing Cycle Phases

Details the startup, wash, disinfectant, rinse, alcohol, and air phases of the reprocessing cycle.

Pre-start Inspection Procedure

Procedure for inspecting the reprocessor before startup, including filter and reservoir checks.

Reprocessor Startup Procedure

Step-by-step guide to starting the reprocessor, including power and air source checks.

Disinfectant Potency Monitoring

Instructions on monitoring disinfectant potency using test strips for effective disinfection.

Disinfectant Warning Override

Procedure to override disinfectant cycle count warnings and continue operation.

Endoscope Disinfection Process

Steps for preparing and running the disinfection process for endoscopes.

Endoscope Leak Testing

Procedure for performing an automated leak test on an endoscope.

Running the Disinfection Process

Detailed steps for running the disinfection process, including ID data and program selection.

Completing the Disinfection Process

Steps for finishing the disinfection cycle, unlatching the lid, and removing the endoscope.

Process Interruption Handling

Procedures for handling system interruptions and operator-initiated interruptions.

Reprocessor Shutdown Procedure

Instructions for safely shutting down the reprocessor at the end of the day.

MAINTENANCE

Maintenance General Overview

Basic maintenance procedures and reference to safety guidelines.

Reprocessor Leveling Procedure

Instructions for installing and adjusting the reprocessor to be level.

Collet Coupling Disconnection and Connection

Instructions for disconnecting and connecting collet couplings used throughout the machine.

Disinfectant Filter Cartridge Replacement

Procedure for changing the disinfectant filter cartridge at recommended intervals.

Internal Water Filter Removal and Replacement

Steps for removing and replacing the internal water filter cartridge.

Printer Paper and Ribbon Replacement

Procedures for replacing printer paper and ribbon for optimal print quality.

Air Filter Replacement Procedure

Instructions for locating and replacing the air filters.

Solenoid Valve Cleaning and Seal Replacement

Procedures for cleaning or replacing the seal on the 3/4-inch solenoid valve.

Flow Sensor Cleaning Procedure

Steps for cleaning the flow sensors to ensure proper operation.

Disinfectant Reservoir Removal

Procedure for safely removing the disinfectant reservoir from the reprocessor.

Fuse Replacement Procedure

Guide to identifying and replacing blown fuses in the reprocessor's electronics.

Leak Tester Option Verification

Procedure for testing the leak tester option to verify its functionality.

Draining Air Chamber Condensation

Instructions for periodically draining condensation from the air chamber.

Manually Unlocking the Lid (Feature Option)

Procedure for manually unlocking the reprocessor lid if the feature option is present.

TROUBLESHOOTING

Troubleshooting General Information

Basic troubleshooting procedures and reference to safety guidelines.

Reprocessor Start-Up Failures

Addresses problems like no power, GFCI trips, or tripped circuit breakers preventing startup.

Disinfection Cycle Start Failures

Troubleshooting steps for when the disinfection cycle does not start due to software or hardware issues.

Water Flow and Fill Problems

Addresses slow water fill, insufficient pressure, plugged filters, and valve issues.

Disinfectant Flow and Drain Problems

Troubleshooting for slow disinfectant fill, drain problems, and hook-up flow.

End of Cycle and Lid Lock Issues

Solutions for scopes remaining wet, lid lock issues, or missing air phase.

Display and Printer Malfunctions

Troubleshooting for unreadable LCD screens or printer malfunctions.

Error and Warning Message Resolution

Explains common error messages like "Bas Sen Err", "Dis Expired", "Dis Warn".

APPENDIX

Error Message Definitions

Lists and defines various error messages displayed on the LCD screen.

Diagnostic Message Explanations

Explains diagnostic messages and the corresponding functions or settings.

Log Message Glossary

Provides definitions for various log messages recorded during operation.

Glossary of Terms

Defines key terms used throughout the manual for clarity.

Reprocessor System Specifications

Details the physical and electrical specifications of the reprocessor.

Disinfection Cycle Chart

Outlines the default and programmable times for each phase of the disinfection cycle.

Custom Program Reference Chart

A table to record custom program settings for future reference.

Reprocessor Flow Diagram

Visual representation of the reprocessor's fluid and air pathways.

Electrical Block Diagram

Illustrates the reprocessor's electrical components and their interconnections.

Setup Menu Functions List

Lists setup functions and their corresponding menu numbers for reprocessor configuration.

Diagnostic Menu Functions List

Lists diagnostic functions with their corresponding numbers for system testing and configuration.

Medivators DSD-201 Specifications

General IconGeneral
BrandMedivators
ModelDSD-201
CategoryMedical Equipment
LanguageEnglish

Related product manuals