Explains how to use the manual, notes, cautions, and warnings.
Outlines general safety guidelines, intended use, and operator precautions.
Covers installation, maintenance, water quality, detergent, disinfectant, and precleaning procedures.
Instructions for moving the reprocessor and ensuring the reservoir cover is in place.
Details water, electrical, air, and drain system requirements for proper operation.
Outlines the procedure for performing a trial run and checks to verify correct installation.
Overview of operator controls and how to set up and program the reprocessor.
Describes the reprocessor's control panel interface and components.
Explains the function and types of LED indicators used for system status and errors.
Details how the LCD screen displays messages, prompts, and program status.
Explains the use of the numeric keypad for entering information and navigation.
Details the purpose and operation of each function key on the control panel.
Explains startup, shutdown, programming, leak testing, and endoscope preparation.
Details the startup, wash, disinfectant, rinse, alcohol, and air phases of the reprocessing cycle.
Procedure for inspecting the reprocessor before startup, including filter and reservoir checks.
Step-by-step guide to starting the reprocessor, including power and air source checks.
Instructions on monitoring disinfectant potency using test strips for effective disinfection.
Procedure to override disinfectant cycle count warnings and continue operation.
Steps for preparing and running the disinfection process for endoscopes.
Procedure for performing an automated leak test on an endoscope.
Detailed steps for running the disinfection process, including ID data and program selection.
Steps for finishing the disinfection cycle, unlatching the lid, and removing the endoscope.
Procedures for handling system interruptions and operator-initiated interruptions.
Instructions for safely shutting down the reprocessor at the end of the day.
Basic maintenance procedures and reference to safety guidelines.
Instructions for installing and adjusting the reprocessor to be level.
Instructions for disconnecting and connecting collet couplings used throughout the machine.
Procedure for changing the disinfectant filter cartridge at recommended intervals.
Steps for removing and replacing the internal water filter cartridge.
Procedures for replacing printer paper and ribbon for optimal print quality.
Instructions for locating and replacing the air filters.
Procedures for cleaning or replacing the seal on the 3/4-inch solenoid valve.
Steps for cleaning the flow sensors to ensure proper operation.
Procedure for safely removing the disinfectant reservoir from the reprocessor.
Guide to identifying and replacing blown fuses in the reprocessor's electronics.
Procedure for testing the leak tester option to verify its functionality.
Instructions for periodically draining condensation from the air chamber.
Procedure for manually unlocking the reprocessor lid if the feature option is present.
Basic troubleshooting procedures and reference to safety guidelines.
Addresses problems like no power, GFCI trips, or tripped circuit breakers preventing startup.
Troubleshooting steps for when the disinfection cycle does not start due to software or hardware issues.
Addresses slow water fill, insufficient pressure, plugged filters, and valve issues.
Troubleshooting for slow disinfectant fill, drain problems, and hook-up flow.
Solutions for scopes remaining wet, lid lock issues, or missing air phase.
Troubleshooting for unreadable LCD screens or printer malfunctions.
Explains common error messages like "Bas Sen Err", "Dis Expired", "Dis Warn".
Lists and defines various error messages displayed on the LCD screen.
Explains diagnostic messages and the corresponding functions or settings.
Provides definitions for various log messages recorded during operation.
Defines key terms used throughout the manual for clarity.
Details the physical and electrical specifications of the reprocessor.
Outlines the default and programmable times for each phase of the disinfection cycle.
A table to record custom program settings for future reference.
Visual representation of the reprocessor's fluid and air pathways.
Illustrates the reprocessor's electrical components and their interconnections.
Lists setup functions and their corresponding menu numbers for reprocessor configuration.
Lists diagnostic functions with their corresponding numbers for system testing and configuration.
| Brand | Medivators |
|---|---|
| Model | DSD-201 |
| Category | Medical Equipment |
| Language | English |