EasyManua.ls Logo

Mellanox Technologies IS5030Q-2SFC - 4.3.2.2 Reprogramming the Switch Through The I2 C Port

Mellanox Technologies IS5030Q-2SFC
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Management and Tools Overview
Rev 3.4
Mellanox Technologies
46
-I- Discovering the fabric - Running: ibdiagnet -skip all
-I- Added 10 in-band devices
2. List the discovered mst inband devices run “mst status”.
[root@mymach]> mst status
MST modules:
------------
MST PCI module loaded
MST PCI configuration module loaded
...
Inband devices:
-------------------
/dev/mst/CA_MT25418_sw005_HCA-1_lid-0x0001
/dev/mst/SW_MT47396_lid-0x0011
/dev/mst/SW_MT48438_lid-0x0003
Identify the switch you want to update according to its description or its LID.
in the examples below we will use SW_MT48438_lid-0x0003 as our target switch.
Query the switch to determine the current firmware version:
[root@mymach]> flint -d /dev/mst/SW_MT48438_lid-0x0003 q
Image type: FS2
firmware Version: 7.3.0
Device ID: 48438
Chip Revision: A0
Description: Node Sys image
GUIDs: 0002c902004177d8 0002c902004177db
Board ID: n/a (MT_0D00110012)
VSD: n/a
PSID: MT_0D00110012
Burn the Infiniscale IV switch:
flint -d /dev/mst/SW_MT48438_lid-0x0003 -i ./fw-IS4-rel-7_4_0-Q_A1.bin -qq b
4.3.2.2 Reprogramming the Switch Through The I2C Port
This interface is for Debug and Troubleshooting only. This interface is for FAEs and advanced
users only.
Use the MTUSB-1 adapter (available from Mellanox) to reprogram the switch firmware using a
server or PC running MFT.
The I2C connector should only be used when the firmware cannot be updated in-band.