5 Service information
Back to contents >
Merrychef conneX
®
service and repair manual
52
Warning Event / Error Codes generated during operations:
Error
Problem
Solution
E84: Invalid
date.
Event log only.
Invalid date
detected at
start-up.
Enter correct date and time in settings. For repeated events, download the latest
firmware from merrycheftechnical.com and load on to the oven.
E98: Incomplete
cleaning.
Event log only.
Cleaning
sequence not
completed by
Operator.
Complete cleaning process as instructed.
E99: Air Filter
Override.
Event log only (for
display see
solution).
Operator
selected
continue when
filter was
removed (filter
microswitch
was open
circuit).
Check filter magnet, filter microswitch & connections.
Operator warning message = “Air filter removed. Please replace the air filter to
continue. (By selecting cancel and overriding the air filter monitoring this will be
logged.).
Information Event Codes:
Error
Problem
Solution
E81: Firmware
updated.
Event log only.
UI or IO
Firmware has
been
updated.
Solution not required
E82: menu
updated.
Event log only.
Menu file has
been
updated.
Solution not required
E86: Soft Power
On.
Event log only.
U/I on switch
used.
Solution not required if events correspond with normal operation.
E87: Completed
Cleaning
Sequence.
Event log only.
Cleaning
sequence
completed.
Solution not required if events correspond with normal operation.
E100: Main
Power On
Event log only
IO board
supplied with
12V once mains
power is
switched on.
Solution not required if events correspond with normal operation.
Error Codes generated during recommission test:
E89: Recommission Cooling Test Failed User input ‘X’ (to confirm not working) or timed out
..E90: Recommission Convection Fan Test Failed User input ‘X’ (to confirm not working) or timed out
E92: Recommission Heater Test Failed <10°C cavity temperature rise within 90 seconds
E93: Recommission Magnetron Test Failed <1.25A current draw recorded on magnetron.
E94: Recommission Filter in Test Failed No user action registered within 10 seconds. Filter microswitch signal
remained open circuit, check filter microswitch & connections.
E95: Recommission Filter Out Failed No user action registered within 10 seconds. Filter microswitch signal
remained closed circuit, check filter microswitch & connections.
E96: Recommission Door Close Failed No user action registered within 10 seconds. Door switch circuit remained.
open circuit, check door switches & connections
E97: Recommission Door Open Failed No user action registered within 10 seconds. Door switch circuit remained.
closed circuit, check door switches & connections