1. Warnings & Suggestions
An S618 is powered primarily via solar energy. If you would like to
power it alternatively through USB-C charging, a required USB-C
Power Delivery 3.0 adapter is not included. When sourcing one,
please note that the adapter must be rated for at least 60W of
output power (20V, 3A minimum) to properly charge the S618.
The S618 can also be powered via DC power supply (12V, >6A) or
802.3af/at Power over Ethernet (PoE) if installed as an add-on.
a. Safety warnings
i. An S618 Installation site typically consists of a high
supporting structure such as a mast, tower or building for
the S618. To prevent injury or loss of life, please take extreme
care when working at heights or near power lines.
ii. Grounding and protective earth:
1. The S618 assembly must be properly grounded through
the mount to protect against lightning. It is the user’s
responsibility to install the equipment in accordance with
national regulations.
2. In the USA, follow Section 810 of the National Electric
Code, ANSI/NFPA No.70-1984 (USA). In Canada, follow
Section 54 of the Canadian Electrical Code. These codes
describe correct installation procedures for grounding the
outdoor unit, mast, lead-in wire and discharge unit, size of
grounding conductors and connection requirements for
grounding electrodes. Other regulations may apply in
different countries and therefore it is recommended that
installation be contracted to a professional installer.
iii. Before servicing the equipment, always power down and
remove it from its installation site.
iv. External cables:
1. Safety may be compromised if outdoor rated cables are
not used for connections that will be exposed to the
outdoor environment. Connections intended to be