4.1.6. Checking the water level of the steam generator (electrically heated models)
It is not allowed to open the control valve of the steam generator if the temperature of the steam jacket
of the kettle is over +100°C. Watch out for releasing hot steam and water when you open the above
mentioned valves.
Check that the kettle is in its upright position.
Open the control valve by turning the handle parallel to the valve.
Control valve of steam generator
Open the water inlet valve, which is under the water inlet funnel, by turning the handle (2) parallel to
the valve.
Let water into the water inlet funnel. Stop fi lling water when water starts to drop out of the control valve.
Close the water inlet valve. Close the control valve when water has stopped running out of it.
The kettle does not heat if there is not enough water in the steam generator. Add water if needed ac-
cording to the instructions.
A white water level indicator light on the control panel displays when water must be added to the steam
generator. If you sometimes use the cooling system (optional), water must not be added at all.
1. Water inlet funnel
2. Handle of the water inlet valve
4.1.7. Emptying of surplus condensate water (steam heated models)
It is not allowed to open the control valve of the kettle jacket, if the temperature of the steam jacket of the
kettle is over +100°C. Watch out for releasing hot steam and water when you open this valve.
Control valve of kettle jacket
Check that the kettle is in its upright position.
Open the control valve by turning the handle parallel to the valve.
The kettle does not heat, if there is a lot of surplus condensate water or undrained cooling water in the
kettle jacket.
STOP
STOP