6.8. Testing the mixer
The basic conditions for the perfect functioning of the mixer are that the kettle is correctly fi xed to the
fl oor according to the installation instructions. The kettle and the kettle pillars must also be in a horizontal
position.
6.8.1. Checking the functions
Switch on the mixer by turning the mixing program selector (7) to position and the speed regulator
(5) slightly away from the 0 position. Check the following functions:
• The mixer is mixing at the lowest speed and the green indicator light (2) illuminates
• The mixer rotates clockwise
• Turn the selector switch to position
turn the speed regulator to position 0 for a while and then turn
it again slightly away from the 0 position
• Check the auto-reverse function: approx. 6 seconds clockwise and approx. 6 seconds counter clock-
wise
• Test the speed of rotation by turning the speed regulator to the maximum position
• Test both preset mixing programs
1. Power regulator
2. Green indicator light (heating ON)
3. Indicator light for low water level (electrically heated models)
Indicator light “steam supply open” (steam heated models)
4. Emergency/stop button
5. Mixing speed regulator
6. Green indicator light (mixer ON)
7. Mixing program selector switch
8. Tilting switch
You will fi nd the speeds and the preset programs in the section “Mixer operation”.