25
VIKING / VIKING COMBI
Rev. 2.0 (1.8.2017)
Operating instructions
Settings
Maximum fi lling amount
• The maximum fi lling amount has been set in the factory according to the kettle size.
• The setting is changed by fi rst pushing the button and immediately after that the button
for 5 seconds, after which the display value starts to blink. The new setting value according to the
kettle size is set using the and buttons. The maximum set value is 400 liters.
• The set value is saved if the setting is not changed in 5 seconds.
Calibration of fl ow measurement
• Basic calibration has always been done in the factory, so normally it need not be done again.
• If, however, calibration is needed, fi rst push the -button and immediately after that the
button for 5 seconds after which the value 855 starts to blink on the display.
• To decrease the fl ow, push the button, so the value decreases. To increase the fl ow, push the
button, so the value increases. The amount of fl ow must be checked by pouring 5 liters of water
into a measuring vessel.
• The set value is saved if the value is not changed within 5 seconds.
4.2.7. Temperature display (option, Viking Combi)
Lämpötilanäyttö
The temperature display shows the temperature of the food (shows the actual temperature of the food
only when the mixer is running)