Stopping the cooling
1. Close the faucet.
2. Remove the cleaning hose from the control valve.
3. Turn the 3-way valve to the cooking position (upwards).
3-way valve in cooking position
4. Let the extra water run out of the steam jacket through the control valve. Close the control valve when
the kettle is in an upright position and water stops fl owing out.
It takes a few minutes to let the extra water run out of the steam jacket. If you fi rst want
to empty the kettle, close the control valve before tilting. If the control valve is open during
the tilting, it is possible that the steam generator gets drained of water, see “Filling the
steam generator” (electrically heated models).
The kettle will not warm up properly if the water level is not lowered to the normal cooking level.
4.2.6. Automatic water fi lling (option)
1. 3-digit display
2. Automatic fl ow on/off
3. Manual fl ow + reset
4. Setting is increasing
5. Setting is decreasing
A desired amount of cold water can be dispensed to the kettle by the automatic water dispenser in the
following way:
• water fi lling is manually kept on until the desired amount of liters appears on the display of the control unit
or
• automatic water running stops when the amount of liters set beforehand in the control unit are achieved.
Automatic water fi lling unit