18.13.4. Setting the energy
Keep pressing the P-E button to switch to the energy generation mode. Auxiliary data display area
shows the time in seconds and the energy delivered to output terminals after pressing the OUTPUT
button given the existing setting of voltage, current, frequency and power factor. Time setting range is
1.1 s to 1999 s.
The energy value can be set in two ways:
Direct setting of energy
Select the energy mode and then keep pressing the center cursor button until [ _ _ _ _ _ _ _ ] symbols
appear under the time value (E = xxx.xxxx) supplemented with indication of the set mode.
The value can be set using numeric keyboard, cursor buttons or potentiometer and confirmed by pressing
Ws/kWs/MWs, VAs/kVAS/MVAs or VArs/kVArs/MVArs display buttons depending on the set mode. The
value can also be confirmed by pressing ENTER.
Time value is recalculated using new set energy.
Setting the time
Select the energy mode and then keep pressing the center cursor button until [ _ _ _ _ _ _ _ ] symbols
appear under the time value (t = xxx.x s).
The value can be set using numeric keyboard, cursor buttons or potentiometer and confirmed by pressing
“s” display button depending on the set mode. The value can also be confirmed by pressing ENTER.
Energy value is recalculated using new set time.

Table of Contents

Other manuals for Metrix CX 1651

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metrix CX 1651 and is the answer not in the manual?

Metrix CX 1651 Specifications

General IconGeneral
BrandMetrix
ModelCX 1651
CategoryTest Equipment
LanguageEnglish

Related product manuals