1.6 WIRING INSTRUCTIONS
1.6.1 CAUTION IN WIRING
• For safety, make sure that wiring is performed by qualied personnel only.
• In order to prevent potential electric shock, wire the unit after turning off the power supply and making sure that the power
is not supplied to the cable.
• Be sure to conrm the name and polarity of each terminal before wiring to it.
• Do not connect anything to unused terminals.
• We offer a series of lightning surge protectors for protection against induced lightning surges. Please contact us to
choose appropriate models.
1.6.2 APPLICABLE WIRE
■ ONE BLOCK TERMINAL
• Applicable wire size: 1.0 – 1.3 mm
2
• Stripped length: 8 mm (0.31”)
■ SEPARABLE TERMINAL
• Applicable wire size: 1.0 – 1.3 mm
2
• Stripped length: 8 mm (0.31”)
IMPORTANT
Tinning wire ends may cause contact failure and therefore is not recommended.
1.6.3 WIRING
(1) Touch at-blade screwdriver into the groove, and then press.
(2) Insert a wire until touching in the back.
(3) Pull out the minus screwdriver. Pull the wire lightly to conrm that it is not pulled off.
IMPORTANT
Take measures to prevent the sheath of wire from being caught in terminal(s) to avoid contact failure.
8mm
8mm
(2)
(1)
(3)
(3)
Wire
Screwdriver