Error description/ troubleshooting
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Squeegee didn’t start moving. Error-
code will be displayed at the station.
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Error screen lift. Check valve and
reed contact. Error-code will be displayed at the
station.
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Foil unit finish signal not received.
Error-code will be displayed at the station.
Error at station parameter setting. Illegal gap in station
addressing.
CAN Bus: Missing Terminal
CAN Bus: Station behind
Terminal
Error at station parameter setting. Stations address
higher then terminal address.
Communication to main drive controller interrupted.
Check wiring.
“Diverse Systemfehler” +
READJUST + Fehlercode +
please call MHM-Service
Please contact MHM service department for further
information.
Functionality not Supported
Wrong firmware on master PCB.
Incompatible Hardware found
Update not possible because of wrong hardware
Functionality not Supported
Wrong software version on PCB
Different Software-Versions
Different software versions on PCBs
Error position sensor signals. Check wiring.
Lift up sensor signal is missing. Check adjusting,
wiring and function of the sensor.
Lift down sensor signal is missing. Check adjusting,
wiring and function of the sensor.
Starting lockout active. Index not possible. Check
input signal.
Off contact signal out of
range
Off contact position signal out of range. Check Master-
PCB parameters and wiring.
Off contact drive timeout
Off contact target not reached. Check mechanics,