Operating Instructions Synchroprint 5000
Operating instructions SP5000 V1-0.docx Page 47 of 52
Safety level cannot be
adjusted.
Safety key is not connected
to the Distribution- PCB.
Check wiring from the safety key to the
Distribution-PCB (see wiring diagram)!
Wrong wiring of safety key
at panel housing.
Put terminal out of housing and check wiring
of the safety key (see wiring diagram)!
Squeegee does not
toggle at squeegee
carriage movement.
Squeegee pressure too low.
Adjust pressure control at print station!
No air pressure at print
station.
Lower pressure stop cock active or tube
snapped off.
Check wiring between station PCB and
squeegee valve (see wiring diagram)!
Unlock screens does
not work.
Wrong low pressure
adjustment.
Check adjustment of precision pressure
regulator.
Check wiring between station PCB, Bus-
PCB and squeegee valve (see wiring
diagram)!
Supply cable of tablet is not
connected.
Connect the supply cable with the tablet.
Booster cylinder
doesn’t work.
No air pressure at booster
cylinder.
Wrong adjustment of lower pressure
regulator or lower pressure stop cock active.
10.2. Error messages control system
Error description/ troubleshooting
Emergency stop circuit interrupted.
Emergency stop button has been pressed.
Safety barrier has been opened.
“Control ON/OFF” is off.
Reset button has not been pressed.
Air pressure too low.
Pressure hose disconnected.
Pressure adjustment too low.
Supply pipe pressure too low.
Error motor control. Check display of motor controller.
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Dryer finish signal not received.
Error-code will be displayed at the station.
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Squeegee target position not reached.
Error-code will be displayed at the station.