Frequently asked questions
127
Problem Possible cause and solution
Check container/lance DOS
Little or no flow has been identified.
Check the level in the supply container. Replace an
empty container with a full one, if necessary.
Check the suction opening of the siphon for deposits.
Prime the dispensing system.
The dispensing hose is kinked.
Remove any kinks from the dispensing hose. Position it
so that it cannot become kinked.
Check the dispensing hose for leaks.
Prime the dispensing system.
Contact Miele Service if there are leaks in the dispensing
hose or a fault with the siphon.
Highly viscous (thick) process chemicals can affect the dispenser monitoring and lead to
inaccurate data. In this instance, please contact Miele Service for advice.