Loading...
OM-230693 Page 12
F
Complete Parts List is available at www.MillerWelds.com
B. Temperature Specifications
Operating Temperature Range* Storage/Transportation Temperature Range
-4 to 104°F (-20 to 40°C) -22 to 122°F (-30 to 50°C)
*Output is derated at temperatures above 104°F (40°C).
4-7. Volt-Ampere Curves
1
0
5
10
15
20
25
30
35
40
0 50 100 150 200 250 300 350
Volt min
Volt max
Amperes
Volts
1 Normal Volt-Ampere Curves
The volt-ampere curves show the normal
minimum and maximum voltage and amper-
age output capabilities of the welding power
source. Curves of other settings fall between
the curves shown.