Chapter 3 Cutting Data with Register Marks
82
Spacing Between Register Marks
The spacing between register marks (D) is as shown below.
Mark shape
Type 1 Type 2
Register mark spacing (D): Register mark length (B)
× 2 to 1,000 mm
D
D
B
B
Register mark spacing (D): Register mark length (B)
× 2 to 1,000 mm
D
D
B
B
l
Mark Origin Mis-detection Example
If the spacing between register marks (D) is narrow, as shown in the figure below, the machine may fail
to detect them.
D
D
B
B
Reading Range of Register Marks
This machine can detect register marks in the range shown in the following figure. If the margin is small, the
edge of the sheet may be incorrectly identified as a register mark.
If expand is disabled, set the distance between the register mark and the inside of the pinch roller to at least
5 mm for Type 1 register marks and at least the length of the register marks for Type 2 marks.
When using long sheets, the sheet may meander, which reduces the distance between the register marks
and inside of the pinch roller. Larger margins are recommended when using long sheets.
Expand: "Expanding the Cutting Area [EXPANDS]"(P. 108)