Chapter 3 Cutting Data with Register Marks
90
Detecting Register Marks Using Full-Automatic Detection
The distance between register marks detected by the plotter is adjusted against the distance between the
register marks printed on the sheet.
First, measure the distances (A and B) between the register marks in the data.
Measure between the register mark center points.
Register mark shape: Type 1
Register mark shape: Type 2
Measured to register mark
centerlines
l
Detection procedure using front specification
The sheet must be loaded from the rear.
1
Measure the distances A and B on the data to be output.
2
Position TP1 as shown in the following figure.
Use "Detecting Register Marks Using Semi-Automatic Detection"(P. 92) if TP1 is not
positioned as shown in the following figure.
5mm
Plotter cut line
Pinch roller
Register mark shape:
Type 1
Register mark shape:
Type 2
3
Pull the clamp lever toward you while ensuring that the sheet does not move.
The sheet is held by the pinch rollers.
4
Press the [ENTER/HOLD] key.
If [ROLL. SELECT] is set to [ON], select the number of pinch rollers to be used. "Setting the
Number of Pinch Rollers to Use"(P. 56)