6-32
Setting the Cleaning Interval in the Standby Mode
This is a function operated instead of the PUMP tube washing when the cleaning solution for maintenance has
been used up.
The cleaning type and the interval between each cleaning operation in the standby mode are set.
1
Press the key in LOCAL to select the
printing mode.
2
Select [ROUTINE SETUP] of the maintenance menu.
(1)Press the key.
(2)Press to select [MAINTENANCE] and press the key.
(3)Press to select [ROUTINE SETUP].
(4)Press the key.
3
Press to select [CLEANING].
4
Press the key.
5
Press to set the interval between each cleaning
operation.
• Set value: OFF or 1 to 168 hours
6
Press the key.
• The cleaning type selection screen appears.
7
Press to select a cleaning type.
• Set value: NORMAL, SOFT, HARD
8
Press the key.
• This function is not performed when ink-related errors, such as "NEAR END" and "INK END", have
been occurring.
• While this function is performed, the screen shows the progress that is the same as that of Head
cleaning and no key operation can be performed. ( P.2-36 "Performing Head Cleaning")
• This function can be performed only when the states shown by the screens below are maintained.
<LOCAL . 1> [ #01 ] *REMOTE. 1* [ #01 ]
0.00m
LOCAL REMOTE
<LOCAL. 1> [ #01 ]
WIDTH:****mm
ROUT I NE SETUP
CLEAN I NG <en t >
ROUT I NE SETUP
CLEAN . I NTERVAL =
1 h
ROUT I NE SETUP
CLEAN . I NTERVAL =
4 h
ROUT I NE SETUP
CLEAN . TYPE :
NORMA L
ROUT I NE SETUP
CLEAN . TYPE :
SOFT
ROUT I NE SETUP
CLEAN . I NTERVAL =
4 h