3-31
3
Extended Functions – Printer –
Machine Settings
Common settings are functions for using this machine easily.
The following items can be set in Machine settings.
Setting the DEODORIZE FAN
The exhaust fan operates during printing. After printing has been complete, it operates according to the setting of
"Stop timer".
The following two items can be set for the exhaust fan.
• STOP TIME : The time until the exhaust fan stops after printing has been completed is set.
• RENEW : When this is set to "ON", the exhaust fan can operate while printing is not performed.
1
Press the key in LOCAL to select the
printing mode.
2
Press the key.
3
Press to select [MACHINE SETUP].
4
Press the key twice.
5
Press to select an item to set.
STOP TIME
: The time until the exhaust fan stops after printing has been completed is set.
RENEW : Select this when you want to operate the exhaust fan.
6
Press the key.
Item
Set Value
*1
*1. The underlined has been set as default.
Overview
DEODRIZE
SETUP
*2
*2. The exhaust fan is optional.
STOP
TIME
OFF /
10 to 120
to 240 min/
CONTINUE
The time until the rotation of the exhaust fan stops after printing
has been completed is set. ( P. 3-31)
RENEW ON/OFF
The present operating state of the exhaust fan is switched.
( P. 3-31)
DRYNESS FEED ON/OFF
It is set whether a medium is fed for it to be dried after printing has
been completed. ( P. 3-32)
STAMP SETUP ON/OFF
The setting for the output date and printing conditions to be output
after printing has been completed is configured. ( P. 3-33)
Waste Ink Warning ON/OFF
It is set whether the confirmation message of the waste ink tank is
displayed. ( P. 6-39)
Tes t P R T. Ar ra ng e
FEED
DIR./
SCAN DIR.
The orientation of test patterns when test printing has been
repeated is set. ( P. 3-34)
• The exhaust fan is an option contained in the drying exhaust unit.
• When this machine is equipped with a drying fan, the fan operates in cooperation with the settings
configured here.
<LOCAL. 1> [ #01 ]
WIDTH:****mm
FUNCT I ON
SETUP <ENT>
FUNCT I ON
MACH I N E S E T UP < E N T >
DEODR I ZE FAN
STOP T I ME <en t >