Loading...
62
Error
No.
Error
level
Error displayed Cause Measures
F469
1 or
2
UNITECH
HEATER
Generic Alarm
Alarm generated in
UNITECH HEATER
1. Remove the cause of alarm of UNITECH
HEATER.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F471
3
Printing position
settings Alarm
Carriage print
position setting error
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F472
3
Carriage
printing height
setting Alarm
Carriage print height
setting error
F473
0 or
2 or
3
Folds Alarm
The media floated
1. Set again so that the media does not float
off the belt.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
If the media continues to float:
3. Adjust the pressure of the pressure roller.
4. Turn on the belt heater.
5. Replace the adhesive.
6. If the above measures do not resolve the
error, tap the [DETAIL] button in the MPC
[SYSTEM ALARM] column, and tap the
[CLEAR ALARM] button.
7. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
8. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F474
3
Carriage lateral
folds safety
device Alarm
Carriage crashed into
the media.
1. Remove the contact media and set it again.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F475
3
Purge quote too
low (3[mm])
Purge position setting
error
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR

Table of Contents

Related product manuals