Error displayed Cause Measures
START -
Maintenance
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
movement
carriage vertical
2
Alarm
detected in the
UNWINDER unit.
1. Check if there is a hole in the media coming
out of the UNWINDER unit . If there is a
hole, feed the media until it comes out of
the print area, then tap the [DETAIL] button
in [SYSTEM ALARM] of the MPC, and tap
the [CLEAR ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
Dancer Roll Up
Alarm
UNWINDER unit has
reached its upper
1. Level the tension bar in the local mode.
2. Check that the operation mode of the
UNWINDER unit is set to Auto.
3. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
4. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
5. If the Alarm appears again, contact your
dealer, our sales office, or call center.
1 or
2
Dancer Roll
Down Alarm
tension bar has
reached its limit.
UNWINDER unit
inverter error
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
Thermal
protection
supply or breaker of
UNWINDER unit
Unwinder in
MANUAL mode
set to manual mode.
1. Set the operation mode to AUTO on the
touch panel of the UNWINDER unit.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.