64
Error displayed Cause Measures
Emergency
Alarm
occurs in DRYERJET
1. Check the following items.
1.1 Check that the DRYERJET
emergency switches (2 places) are
released. At this time also check
whether the emergency switch on the
main unit is released.
1.2 Make sure that there is no clogging
near the media insertion slot of
DRYERJET.
1.3 Check that the area sensor of the
DRYERJET is not shielded.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
Thermal
supply or breaker
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
Inverter Alarm
error
Cardan Alarm
Big Roll UNWINDER
1. Check the connection part of the Big Roll
Cardan joint.
If the cardan joint is not connected to the
trolley, connect it.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.