EasyManua.ls Logo

MIMAKI ML Tiger-1800B MKII - PLC Error List: Seam, Paper, and Dancer Errors; Specific PLC Error Codes and Solutions

MIMAKI ML Tiger-1800B MKII
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
Error
No.
Error
level
Error displayed Cause Measures
F542
1 or
2
Seam detected
alarm
Detected a media
seaming at the Small
Roll UNWINDER.
1. Check if there is a seam near the Small
Roll Seam Detector sensor.
If there is a joint, feed the media until the
joint comes out of the print area.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F544
2
DRYERJET
Breaking Paper
Alarm
Media error on
DRYERJET
1. Check the following items.
1.1 Reset the media.
1.2 Level the tension bar in the local
mode.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F545
2
DRYERJET
Dancer UP
Alarm
The tension bar of the
DRYERJET has
reached its upper
limit.
1. Level the tension bar in the local mode.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F546
1 or
2
DRYERJET
Dancer DOWN
Alarm
The tension bar of the
DRYERJET has
reached its lower
limit.
F547
2
DRYERJET
Paper
Temperature
Alarm
Media temperature
error on DRYERJET
1 Check if the heater set temperature is 80
degree C or less.
2 Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3 If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4 If the Alarm appears again, contact your
dealer, our sales office, or call center.
F548
2
DRYERJET
Heating generic
Alarm
Heater error on
DRYERJET
F549
2
By Pass
DRYERJET
Alarm
Bypass of
DRYERJET is
enabled by WinGP.
1 Contact your dealer, our sales office, or call
center.

Table of Contents