66
Error
No.
Error
level
Error displayed Cause Measures
F550
2
DRYERJET
Heater Timeout
Alarm
The heater operation
of DRYERJET timed
out.
1. While the printer is waiting, turn off
DRYERJET [DRYER] switch.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F592
0
Unwinder
Bypass
UNWINDER bypass
1. Change the [Unwinder disabled] to
"Enable" from the [SETTING]-[Machine]-
[Winder-Unwinder] menu of MPC.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
F594
0
Winder Bypass
Winder bypass
1. Change the [Winder disabled] to "Enable"
from the [SETTING]-[Machine]-[Winder-
Unwinder] menu of MPC.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
F599
Carriage Safety
Switch Alarm
Carriage left/right limit
switch error
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
3. If the Alarm appears again, contact your
dealer, our sales office, or call center.
F600
2
Liv3PlcAlarm
Error of Level 3
F601
2
Liv4PlcAlarm
Error of Level 4
F602
1
Liv2PlcAlarm
Error of Level 2
F603
3
Liv5PlcAlarm
Error of Level 5
1. Check the following items.
1.1 Make sure that the 4 emergency
switches on the main unit have been
released.
1.2 Make sure that the machine covers (6
places) are completely closed.
1.3 Make sure that the maintenance
cover is completely closed.
1.4 Check whether there is something
shading the area sensor.
2. Press the emergency reset switch.
3. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
4. Turn off the power of the internal PC and
then the main power of the machine in this
order, and then turn on again after a while.
5. If the Alarm appears again, contact your
dealer, our sales office, or call center.