76
Error
No.
Error
level
Error displayed Cause Measures
MDC Connection_Error
C1 01 0
C101:00(ZZZZZZZZ)Command
Format ERROR
Communication error
between control PC
and FW
Turn off the power in the
order of the internal PC and
the main power of this
machine, check the
Ethernet connection
between the internal PC and
the PCB, and then turn on
the power again.
If it appears again, contact
your dealer, our sales office,
or call center.
C1 02 0
C102:00(ZZZZZZZZ)Notify recive
ERROR
ZZZZZZZZ indicates the
command code (information for
developers).
Processing result
cannot be received
from the Firmware.
C1 03 0
C103:00(ZZZZZZZZ)Respons
recive ERROR
ZZZZZZZZ indicates the
command code (information for
developers).
No response from the
Firmware.
C1 04 0
C104:00(ZZZZZZZZ)Parameter
read ERROR(1)
The operation request
parameter cannot be
received.
C1 05 0
C105:00(ZZZZZZZZ)Parameter
read ERROR(2)
The operation request
parameter cannot be
received.
C1 06 0
C106:00(ZZZZZZZZ)Respons set
ERROR
Receive invalid
parameters from FW
C1 07 0
C107:00(ZZZZZZZZ)Notice
Respons ERROR
ZZZZZZZZ indicates the
command code (information for
developers).
Receive error
completion notification
from FW
C1 10 2
C110:00(ZZZZZZZZ)Communicat
ion ERROR(MDL)
Connection error
between FW and
control PC
C1 11 2
C111:00(ZZZZZZZZ)Communicat
ion ERROR(MRL)
Connection error
between FW and
control PC
MDC Command_Error
C2 01 0
C201:00(ZZZZZZZZ)MG
Command ERROR
Received undefined
MG command
Turn off the power of the
internal PC and then the
main power of the machine
in this order, and then turn
on again after a while.
If it appears again, contact
your dealer, our sales office,
or call center.
MDC Print_Error
C3 01 2
C301:00(ZZZZZZZZ)File read
ERROR
Cannot read the
specified file.
Turn off the power of the
internal PC and then the
main power of the machine
in this order, and then turn
on again after a while.
If it appears again, contact
your dealer, our sales office,
or call center.
C3 02 0
C302:00(ZZZZZZZZ)Parameter
is not set
Operating parameter
does not exist.
C3 03 0
C303:00(ZZZZZZZZ)Parameter
illegal ERROR
Invalid operation
parameter