DP-10/DP-10T/DP-11/DP-15/DP-18
Digital Ultrasonic Diagnostic Imaging System
Operators Manual
[Basic Volume]

Table of Contents

Questions and Answers

  • L
    Lisa BakerJul 28, 2025
    What to do if my Mindray Diagnostic Equipment system does not work after powering on?
    • S
      sandovalebonyJul 28, 2025
      If your Mindray Diagnostic Equipment system fails to power on, try the following: First, power off the system completely. Then, check to ensure the power cable is securely connected to the outlet and verify that the power supply is functioning correctly. Finally, turn the system back on.
  • J
    joel60Aug 4, 2025
    Why does my Mindray DP-10 Diagnostic Equipment screen display characters but no images?
    • J
      jamesmaxwellAug 4, 2025
      If your Mindray Diagnostic Equipment screen shows characters but no images, check these items: Ensure the transducer is properly connected to the system. If the image is frozen, unfreeze it. Adjust the image by turning the gain knob or pressing TGC keys. If the screen still shows no images, power the system off, wait at least 10 seconds, and then power it back on.
  • A
    Alexis TurnerAug 9, 2025
    What to do if the screen of my Mindray Diagnostic Equipment displays abnormally?
    • D
      Dawn MillerAug 9, 2025
      If the screen display of your Mindray Diagnostic Equipment is abnormal, turn off the system, wait for at least 10 seconds, and then turn it on again.
  • E
    erikbarrettAug 15, 2025
    What to do if my Mindray Diagnostic Equipment system works but the screen does not display anything?
    • N
      Nicole SchroederAug 15, 2025
      If your Mindray Diagnostic Equipment system is running but the screen remains blank, try these steps: First, adjust the screen's brightness and contrast using the brightness and contrast knobs. If the screen remains blank, power off the system, wait at least 10 seconds, and then power it back on.
  • P
    Patrick HansenAug 21, 2025
    What to do if my Mindray DP-10 image is abnormal?
    • J
      Jose PayneAug 21, 2025
      If the image on your Mindray Diagnostic Equipment appears abnormal, try selecting a proper exam mode and adjust the image.

Summary

Important Information

Safety Precautions

System Basics

Control Panel

Explains the layout and function of the system's control panel keys.

Interface Elements and Operations

Introduces the software interface and how to operate its elements.

System Connection

Connecting Power Supply

Instructions for connecting the system's power plug to a suitable outlet.

Connecting Equipotential Terminal

Details on connecting the equipotential terminal for safety.

Connecting Transducer

Procedure for connecting and disconnecting transducers to the system.

Startup;Shutdown

Startup

Step-by-step guide for safely starting the ultrasonic system.

Shutdown

Procedures for properly shutting down the ultrasonic system.

Beginning Exam

Inputting Patient Information

Guide on entering patient data for accurate diagnosis and record-keeping.

Selecting Exam Mode

How to choose the appropriate exam mode for different examinations.

Image Control and Adjustment

Adjusting Image Parameters

Details on adjusting parameters like gain, acoustic power, and frequency.

Measurements

General Procedure of Measurements

Outlines the general steps for performing measurements.

File System

Saving Files

Procedure for saving image files to a storage device.

Transducers and Biopsy

Transducers Cleaning and Disinfection

Procedures for cleaning and disinfecting transducers.

Biopsy Guide

Information and warnings related to using the biopsy guide.

Clean and Sterilize the Needle-guided Bracket

Procedures for cleaning and sterilizing needle-guided brackets.

System Maintenance

Maintenance Performed by Users

Describes routine maintenance tasks performed by the system user.

Maintenance Performed by Service Engineers

Details maintenance tasks performed by trained service personnel.

Troubleshooting

Mindray DP-10 Specifications

General IconGeneral
Gray Scale256 levels
Weight5.5 kg
Imaging ModesB, B/B, 4B, M
Frequency2.0 to 10MHz (depending on the transducer)
Cine Loop256 frames
Power SupplyAC 100-240V, 50/60Hz
Image StorageBuilt-in storage, USB flash disk