Sequence of [net lling] with lling signals "coarse/ne"
①
Taring:
The current weight is saved as the tare and
the net weight starts at zero.
②
Coarse:
A coarse ow (coarse and ne) is batched
until the preset value is reached.
③
Fine:
A ne ow is batched until the switch-o
point (overshoot) is reached.
④
Calming:
Time to wait during which the overshoot is
eective and scale vibrations may settle.
⑤
Tolerance Checking:
The weight is determined and checked
against the tolerance values.
8.3.1.2 Net decrease (B4)
The scale is automatically discharged up to the specied value. The other parameters and
the process correspond to the "Net lling" mode; see Chapter 8.3.1.1.
Net = gross - tare
Tare = gross
Transmitter Series PR 5220 8 Production
Minebea Intec EN-160