Model | FX-2003-6DS |
---|---|
Type | Fire Alarm Control Panel |
Zones | 6 |
Output | 24V DC |
NAC Outputs | 2 |
Voltage | 24 VDC |
Battery Capacity | Up to 18 Ah |
Output Voltage | 24V DC |
Enclosure Material | Steel |
Color | Red |
Input Voltage | 120VAC |
Operating Temperature | 0°C to 49°C |
Certifications | UL |
Overview of the FX-2000 Intelligent Analog Fire Alarm Control Panel (FACP).
Lists key features of the FX-2000 system, including capacity, modular design, and power.
Defines terms like "circuit" and "zone" in the context of the FX-2000 system.
Explains different wiring configurations for initiating circuits, NAC circuits, and addressable loops.
Lists different FX-2000 chassis models with their images.
Describes the various adder modules used with the FX-2000 system.
Describes auxiliary modules like PR-300, UDACT-300A, and IPS-2424DS.
Lists and describes the different enclosures used with the FX-2000 system.
Describes the flush trim ring accessory for enclosures.
Lists and describes remote annunciator panels compatible with the FX-2000.
Describes the batteries used with the FX-2000 system.
Lists other accessories like End-of-line Resistor Plate, Remote Trouble Indicator.
Provides diagrams and instructions for installing various enclosures.
Details the material and dimensions for BBX-1072ADS/ARDS enclosures.
Details the material and installation instructions for the BB-5008 enclosure.
Details the material and installation instructions for the BB-5014 enclosure.
Details dimensions and installation for UB-1024DS and DOX-1024DS/R enclosures.
Details dimensions and finish for the FX-2003-12XTDS enclosure.
Shows side views of surface and flush mounting for BBX-1024XT/R.
Illustrates a cross-section of the BBX-1024XT enclosure with trim ring.
Provides general instructions for installing the chassis into enclosures.
Details mounting the chassis using hex nuts into specific enclosures.
Details mounting the chassis using hex nuts into BB-5008/BB-5014 enclosures.
Details mounting the chassis using hex nuts into UB-1024DS/DOX-1024DS/R enclosures.
Describes mounting in UB-1024DS backbox and supports three circuit adder modules.
Describes mounting in BBX-1072ADS/BBX-1072ARDS and supports display/adder modules.
Describes mounting in BB-5008/BB-5014 and supports display/adder modules.
Describes mounting in BB-5008/BB-5014 and supports display/adder modules.
Describes mounting boards for adder and display modules in BBX-1024XT chassis.
Lists adder modules and the chassis they mount in.
Lists display modules and the chassis they mount to.
Details jumpers and connectors on the main fire alarm module board.
Details jumpers and connectors on the super main fire alarm module board.
Describes cable connections for the DSPL-420 main display module.
Describes cable connections for the optional DSPL-420-16TZDS display module.
Describes cable connections for the RAX-1048TZDS zone display module.
Describes cable connections for the IPS-2424DS module.
Describes the FDX-008W/WKI modules and their operation.
Explains the operational modes of the FDX-008W/WKI module.
Provides an example of using the FDX-008W/WKI module for fan control.
Details jumpers and connections for the DM-1008A module.
Details components and jumpers for the SGM-1004A module.
Explains the three operating modes for the SGM-1004A module.
Lists jumper settings for bell cut operation.
Lists jumper settings for isolator mode.
Details connectors and jumpers for the RM-1008A module.
Details hardware configuration and jumper settings for the PR-300 module.
Details jumpers, cable connectors, and miscellaneous items on the UDACT-300A board.
Describes power, RS-485, DIP switches, and jumpers for the ALC-198S module.
Describes power, RS-485, DIP switches, and jumpers for the ALC-396S module.
Describes power, RS-485, jumpers, and connectors for the ALC-H16 module.
Shows terminal connections for the main fire alarm module.
Explains wiring for analog loops.
Illustrates Class B wiring for analog loops.
Illustrates Style 7 wiring for analog loops using isolators.
Illustrates Style 6 (Class A) wiring for analog loops.
Shows Class B wiring for single loop modules like ALC-198S.
Shows Style 7 wiring for single loop modules.
Shows Style 6 wiring for single loop modules.
Details terminal connections for the DM-1008A detection module.
Details terminal connections for the SGM-1004A NAC signal module.
Shows terminal connections for the RM-1008 relay module.
Details wiring for the PR-300 module.
Details telephone line connections for the UDACT-300A.
Details how to connect the power supply to the main chassis.
Provides wiring tables for initiating circuits and NAC circuits.
Lists pre-power-on checks for system installation.
Step-by-step guide for powering up the fire alarm control panel.
Lists common messages and their descriptions for troubleshooting.
Explains the use of paper labels for buttons and indicators.
Describes common indicators like Buzzer, AC On LED, Alarm ACK LED, etc.
Introduces common controls like LCD Display and ACK buttons.
Describes the function of cursor buttons and Enter/Cancel/Menu/Info buttons.
Explains the function of the Signal Silence button.
Explains the function of the Lamp Test button.
Details the functions performed by the System Reset button.
Explains the function of the Fire Drill button.
Explains the function of the General Alarm Cancel button.
Explains the function of the General Alarm button.
Describes how the system operates in a single stage alarm mode.
Describes how the system operates in a two-stage alarm mode.
Explains the panel configuration for pre-signal operation.
Describes the UUKL feature used with specific modules.
Explains the output circuit delay timer feature.
Defines different types of circuits used in the system.
Details types of initiating circuits like Non-Verified, Verified, Water-Flow alarms.
Details types of NAC circuits like Silenceable, Non-Silenceable, Coded Signal, Strobe.
Explains different evacuation codes (Continuous, Temporal, March, California, Alert).
Lists detailed specifications for FX-2003-6DS and FX-2003-6DS-16LED chassis.
Lists specifications for various FX-2000 series chassis models.
Lists specifications for FX-2017-12ADS and FX-2017S-12ADS chassis.
Lists technical specifications for FX-2000 system modules and annunciators.
Lists system model, type, standards, and installation compliance.
Lists UL-compatible addressable loop devices from Mircom and System Sensor.
Lists UL-compatible two-wire smoke detectors from Apollo, Sentrol-ESL, Detection Systems, Hochiki.
Lists UL-compatible four-wire smoke detectors.
Lists UL-compatible signalling devices from System Sensor and Wheelock.
Lists ULC-compatible addressable loop devices from Mircom and System Sensor.
Lists ULC-compatible hardwire smoke detectors.
Lists compatible synchronized modules and strobes.
Lists power requirements (standby and alarm currents) for system modules.
Formula for calculating total current requirement.
Formula for calculating battery capacity requirement.
Guidance on selecting the main chassis based on current.
Guidance on selecting batteries based on capacity.
Details RA-1000 and RAM-200 series remote annunciators.
Lists specific models in the RA-1000 and RAM-200 series.
Describes graphic annunciator models like MGD-32 and AGD-048.
Lists enclosures for remote annunciators.
Describes the RAX-LCD remote shared display.
Lists models for RAX-LCD and related modules.
Lists enclosures for RAX-LCD related products.
DIP switch settings for RA-1000 annunciator.
DIP switch settings for MGD-32 graphic annunciator.
DIP switch settings for RAX-LCD.
DIP switch settings for RAM-208/216.
Defines terms used in the warranty section.
General warning about MGC Systems.
Important information for installers regarding informing end-users.
Discusses reasons for system failure like inadequate installation/testing.
Details requirements for proper system installation.
Emphasizes the importance of regular testing and maintenance.
Stresses the need for user training on system operation.
Discusses occupant response time and detector limitations.
Explains impact of power interruptions and voltage fluctuations.
Discusses battery failure and maintenance requirements.
Explains how obstructions can affect sensor operation.
Discusses impairments to audible notification appliances.
MGC's warranty disclaimer regarding software operation.
Explains how telephone line issues can cause system failure.
System failure due to component failure.
States MGC System is not a substitute for insurance or prudent action.
Details the warranty period and MGC's repair/replace options.
Explains warranty terms for international customers.
Lists conditions that will void the product warranty.
Outlines the steps to obtain warranty service.
Disclaims all warranties other than the one stated.
Explains procedures and fees for out-of-warranty repairs.