EasyManua.ls Logo

Mircom FX-2000 series

Mircom FX-2000 series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For the latest compatability information visit www.mircom.com/deviceguide
FX-2000
Intelligent Analog Fire Alarm Control Panel
LT-657 Rev 15
December 2016
Installation and Operation Manual

Table of Contents

Other manuals for Mircom FX-2000 series

Questions and Answers:

Mircom FX-2000 series Specifications

General IconGeneral
TypeFire Alarm Control Panel
DisplayLCD
NetworkOptional
CommunicationRS-232, RS-485
ProgrammingVia keypad or PC
SLC Loops1
NAC Outputs4
Communication (Additional)Optional Ethernet
Input Voltage120 VAC or 240 VAC, 50/60 Hz
Battery Charging Current1.5 A
Auxiliary Power Output24 VDC
Operating Temperature0°C to 49°C (32°F to 120°F)
Relative HumidityUp to 93% non-condensing

Summary

Document Conventions

Circuits and Zones

Defines "circuit" and "zone" for FX-2000 system interfaces and protected areas.

Wiring Styles

Explains Class A, Class B, Style 4, 6, 7 wiring for initiating, NAC, and addressable loops.

Introduction

About the FX-2000

Describes the FX-2000 FACP, its analog loop controller, and supported modules.

Overall Features

Lists key features and capabilities of the FX-2000 system, including capacity and modular design.

System Components

Adder Modules

Describes various adder modules used with the FX-2000 system, such as loop controllers and circuit modules.

Auxiliary Modules

Details auxiliary modules like PR-300 and UDACT-300A for specific functions.

Enclosures

Lists and describes the different enclosures available for FX-2000 systems, including dimensions.

Remote Annunciators

Lists and describes remote annunciator panels for the FX-2000, including graphical and text-based models.

Mechanical and Chassis Installation

Mechanical Installation Diagrams

Provides diagrams for mechanical installation of various enclosure types.

Chassis Installation

Provides general instructions for mounting the main chassis into different enclosures.

Module Mounting Locations

FX-2003-6 DSFX-2003-12 DSFX-2003-6 DS-16 LED Compact Main Chassis

Shows module mounting locations for FX-2003 series compact main chassis.

FX-2017(S)-12 DS Mid-size Main Chassis

Shows module mounting locations for FX-2017 mid-size main chassis.

FX-2009(S)-12 DS Large Main Chassis

Shows module mounting locations for FX-2009 large main chassis.

Display and Adder Modules Mounting Locations

Mounting the Boards to the BBX-1024 XT Chassis

Describes how to mount boards and modules to the BBX-1024XT chassis.

Module Settings

Main Fire Alarm Modules (MD-764 Part of Main Chassis)

Details settings, jumpers, and connectors for the main fire alarm module.

Main Fire Alarm Super Module (MD-757 Part of S Version Main Chassis)

Details settings, jumpers, and connectors for the Super Main Module.

Fan Damper Control Display Module (FDX-008 WWKI)

Details operation and settings for Fan Damper Control modules.

DM-1008 A Hardwire Detection Adder Module

Details jumpers and connections for the DM-1008A hardwire detection adder module.

SGM-1004 A Hardwire NAC Signal Adder Module

Details components, jumpers, and connections for SGM-1004A NAC module.

RM-1008 A Hardwire Relay Adder Module

Details connections and jumpers for the RM-1008A hardwire relay adder module.

Polarity Reversal and City Tie Module (Model PR-300)

Details connections, jumpers, and wiring for the PR-300 module.

UDACT-300 A Main Board

Details jumpers, LEDs, and cable connectors for the UDACT-300A main board.

ALC-198 S Single Intelligent Analog Loop Controller Module

Details power, RS-485, DIP switches, and jumpers for the ALC-198S module.

ALC-396 S Dual Intelligent Analog Loop Controller Module

Details power, RS-485, DIP switches, and jumpers for the ALC-396S module.

ALC-H16 Hardwire Loop Controller Module

Details power, RS-485, jumpers, and connectors for the ALC-H16 module.

Field Wiring

Main Fire Alarm Module Terminal Connections

Shows terminal connections for the main fire alarm module and its various outputs.

Analog Loop Wiring

Explains analog loop wiring configurations, including Class B, Style 7, and Style 6.

Detection Module (DM-1008 A) Terminal Connections

Shows terminal connections for the DM-1008A hardwire detection module.

NAC Signal Module (SGM-1004 A) Terminal Connections

Shows terminal connections for the SGM-1004A NAC signal module.

Power Supply Connections

Details power supply connections, ratings, and battery fuse information.

System Checkout

Before Turning the Power On

Lists pre-power on checks for the FX-2000 system, including wiring and connections.

Power-Up Procedure

Step-by-step procedure for powering up the FX-2000 system correctly.

Troubleshooting

Lists common system messages like Circuit Trouble, Ground Fault, and Battery Trouble.

Indicators and Controls

Common Indicators

Lists and describes common indicators on the panel, such as LEDs for AC On, Alarm, Trouble.

Common Controls

Details common controls on the panel, including ACK buttons, cursor buttons, and function buttons.

ACK (Queue) Buttons

Explains the function of ACK buttons used to acknowledge alarm, supervisory, and trouble queues.

Operation

Single Stage Operation

Describes how the system operates in a single stage alarm mode.

Two Stage Operation

Describes how the system operates in a two stage alarm mode.

Initiating (Detection) Circuit Type

Details different types of initiating circuits like Non-Verified Alarm and Water-Flow Alarm.

NAC (Signal) Circuit Types

Details different types of NAC circuits, including Silenceable, Non-Silenceable, Coded, and Strobe.

Evacuation Codes

Explains evacuation codes and patterns like Continuous, Temporal, March, and California Code.

Appendix A: Specifications

FX-2003-6 DS and FX-2003-6 DS-16 LED Specifications

Lists detailed specifications for FX-2003-6DS and FX-2003-6DS-16LED chassis.

FX-2003-12 DS, FX-2003-12 XTDS, FX-2009-12 DS, FX-2009 S-12 DS Specifications

Lists detailed specifications for FX-2003-12DS/XTDS and FX-2009 series chassis.

FX-2017-12 ADS and FX-2017 S-12 ADS Specifications

Lists detailed specifications for FX-2017-12ADS and FX-2017S-12ADS chassis.

FX-2000 Specifications System Modules and Annunciator Specifications

Lists specifications for various FX-2000 system modules and annunciators.

Appendix B: Compatible Devices

FX-2000 Series Compatible Addressable Loop Devices (UL)

Lists UL compatible addressable loop devices for the FX-2000 series.

FX-2000 Series Compatible Two-Wire Smoke Detectors (UL)

Lists UL compatible two-wire smoke detectors for the FX-2000 series.

FX-2000 Series Compatible Four-Wire Smoke Detectors (UL Listed)

Lists UL compatible four-wire smoke detectors for the FX-2000 series.

FX-2000 Series Compatible Signalling Devices (UL Listed)

Lists UL compatible signalling devices for the FX-2000 series.

FX-2000 Series Compatible Addressable Loop Devices (ULC)

Lists ULC compatible addressable loop devices for the FX-2000 series.

FX-2000 Series Compatible Hardwire Smoke Detectors (ULC)

Lists ULC compatible hardwire smoke detectors for the FX-2000 series.

Appendix C: Power Supply and Battery Calculations

Power Requirements (All currents are in amperes)

Table of power requirements for FX-2000 system components.

Battery Capacity Requirement:

Formula and guidance for calculating battery capacity based on standby and alarm currents.

Appendix D: Remote Annunciator Panels

RA-1000 & RAM-200 Series

Details RA-1000 and RAM-200 series remote annunciators and their models.

RAX-LCD

Describes the RAX-LCD remote shared display and its features.

Appendix E: DIP Switch Settings Summary

RA-1000

DIP switch settings summary for RA-1000 series devices.

MGD-32

DIP switch settings summary for the MGD-32 device.

RAX-LCD

DIP switch settings summary for the RAX-LCD device.

Appendix F: Alarm Verification Timing

ALC-396 S

Details alarm verification timing specific to the ALC-396S module.

Appendix H: Label Requirements for Zone Identification

Appendix G: Wiring For Supervised Output Module

Figure 48 UL 864 Wiring for Addressable Supervised Output Module

Wiring diagram for addressable supervised output modules per UL 864 standard.

Master Warranty and Warning Information

System Failures

Discusses potential reasons for system failures.

Inadequate Installation

Emphasizes the importance of proper installation according to codes.

Inadequate Testing

Highlights the need for regular system testing and maintenance.

Power Failure

Explains issues related to power interruptions and their impact.

Battery Failure

Discusses potential battery failures and requirements for system operation.

Warranty

Limited Warranty

Details the terms of the limited warranty for MGC products.

Conditions to Void Warranty

Lists conditions that can void the product warranty.

Warranty Procedure

Outlines the steps for obtaining warranty service for products.

Out of Warranty Repairs

Describes the process for obtaining repairs for out-of-warranty products.

Disclaimer of Warranties

Provides a legal disclaimer regarding product warranties.

Related product manuals