Stall prevention operation levle
~
An
overload
(excessive
torque)
can be prevented when
driving
a
motor
with
a
capacity
smaller
than
the
inverter
by
changing
the
stall
prevention
operation
current
level.
This
will
also
function
during
acceleration/deceleration.
The
operation
current
level is
set
with
setting
values
(codes).
Setting
Operation level
Setting
Operation level
Setting
Operation level
value
value value
,
110%
5
150%
9
190%
2
120%
6
160%
'0
200%
3
130%
7
170%
Stall
preventiqn
0
is
not
activated.
4
140%
8
180%
[Factory
setting]
.....
5
(150%)
The
operation
level
%
indicates the
ratio
to the inverter
rated
output
current
-31-