Overcurrent
shut
down
(during
acceleration/deceleration/
Protection/warning
function
constant
speed), regenerative overvoltage
shut
off.
electronic thermal overload. stall prevention
Ambient temperature
-10
to +50°C
(-10
to +40°C for
totally
enclosed
type)
(with
no freezing)
»,
Ambient humidity 90% RH or less
(with
no dew condensation)
•
fr
Storage
temperature
*9
-20
to +65°C
is
Indoors
with
no corrosive or flammable gases. oil mist or
Atmosphere
dust
Altitude/vibration
Less
than
1000m above sea level.
5.9m/S'(O.6G)
or less
-51-
1,000
5,000
HP
rating
o to ,
(Note)
*8.
The braking torque shows the
short
time average deceleration torque when the motor
without
load is decelerated in the shortest time from 60Hz (changes due to motor's loss), and is not
the continuous regenerative torque. For deceleration from a frequency
that
exceeds the base
frequency. the average deceleration torque value will decrease.
A brake resister is not built-in and
cannot
be extemally installed.
1.5K is not available for the single phase input series.
*9. This is a
short
time temperature
for
during transportation, etc.
*10. The low-acoustic noise series use the high carrier frequency sinusoidal PWM control.
*11. The
output
current is displayed only while the SET key is being pressed.
*12. Short Cirunit Ratings
The drive is suitable
for
use on a circuit capable of delivering not move
than
* RMS
symmetrical Amperes.