(Note)
*1.The heat cumulative
data
in the electronic thermal relay will be initialized when the inverter is reset
*2.
The stall prevent operation current can be set freely. The default setting is 150%.
*3. An
alarm
signal will not be
output
when this protective function activates. If the voltage is
insufficient
(main
circuit DC voltage is 23DVor less) when
the
power Is
turned
on. ·0 [; . will
display for approximately 10 seconds and then the insufficient voltage display "Uu .. will appear.
(No
key pad operation will be accepted during the display
of'O
.a
",)
If
the
main circuit DC voltage is higher
than
standard
tolerance when the power is
turned
on,
the
display
·,crU
•will appear. and if the voltage does not lower within 10 seconds,
the
display
" r
• U
'.JI
• (cvervclteae
shut
down) will appear.
-58-