2. Wiring and Connection
2 - 23
(3-2) Connection for full-closed synchronous control
(when using MDS-C1-V1 drive unit and analog output linear scale)
MDS-C1-V1
(Slave axis)
MDS-C1-V1
(Master axis)
Linear scale
CNL3H2
Detector
converter
unit
MDS-B-HR
CON1CON2
CON3CON4
CNL3H1
CN2
CN3
CN2
CN3
Master axis
Slave axis
Detector cable
CNV12
Parameter settings
No. Abbrev. Parameter name Description
Set the detector type. (Refer to Chapter 3 Setup for details)
Master axis Speed command synchronous control : A0xx or A1xx or A2xx
SV025 MTYP Motor/detector type
Slave axis Speed command synchronous control : D0xx or D1xx or D2xx
(Note) The full-closed system using two MDS-C1-V1 units is not compatible with current command synchronous control.