2. Wiring and Connection
2 - 24
(3-3) Connection for full-closed synchronous control
(when using MDS-C1-V1 drive unit and MP scale)
MDS-C1-V1
(Slave axis)
MDS-C1-V1
(Master axis)
MP scale
/D converter
MDS-B-SD
Signal distribution unit
CN3B
CN3A
CN3
CN2B
CN2A
CN2
CN3CN2CN3
CN2
Master axis
Slave axis
Detector cable
CNV12
Parameter settings
No. Abbrev. Parameter name Description
Set the detector type. (Refer to Chapter 3 Setup for details)
Master axis Speed command synchronous control : A1xx or A2xx
SV025 MTYP Motor/detector type
Slave axis Speed command synchronous control : E1xx or E2xx
(Note 1) The MP scale (high-speed serial interface) is compatible only for the high-gain mode.
(Note 2) The full-closed system using two MDS-C1-V1 units is not compatible with current command synchronous control.