FX-TRN-BEG-E F: Advanced Challenge 6
B-64
6.1 Automatic Door Operation
6.1.1 Training Screen
6.1.2 Device Assignment
Category F: Advanced Challenge
Exercise F-1. Automatic Door Operation
Objective Control the door which opens or closes when detecting an object.
Difficulty Level 3 (
★★★
)
Score (Class) 290 (Advanced programming)
Type Device No. Device name Operation
Input
X0 Lower limit ON when door reaches lower limit.
X1 Upper limit ON when door reaches upper limit.
X2 In gate sensor ON when object approaches the door.
X3 Out sensor ON when object leaves the door.
Output
Y0 Door up Moves up when Y0 is ON.
Y1 Door down Moves down when Y1 is ON.
Y6 Light Lit when Y6 is ON.
Y7 Buzzer Sounds when Y7 is ON (Lamp on screen is lit).