255
EDCON, EDCONP
1
2
3
4
6
7
8
6.3 Data conversion instructions
6.3.17 EDCON, EDCONP
Program Example
(1) The program which converts 64-bit floating-point real number of the devices, D10 to D13, into 32-bit floating-point real
number when X0 turns ON, and outputs the conversion result to the devices, D0 to D1.
[Ladder Mode] [List Mode]
Step
Instruction
Device