7. PARAMETERS
7 - 65
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PT26
*TOP2
Function
selection T-2
_ _ _ x Electronic gear fraction clear selection
0: Disabled
1: Enabled
Selecting "Enabled" will clear a fraction of the previous command by the electronic
gear at start of the automatic operation.
Setting "2" or more to this digit will be "Disabled".
0h
_ _ x _ Current position/command position display selection
Select how to display a current position and command position.
0h
Setting
value
Displayed
data
Operation
mode
Status display
Current position Command position
0
Positionin
g display
Auto/Manua
l
Actual current
position is
displayed as
machine home
position is 0.
Command current
position is
displayed as
machine home
position is 0.
1
Roll feed
display
Automatic
Actual current
position will be
displayed as
automatic
operation start
position is 0.
When ST1
(Forward rotation
start) or ST2
(Reverse rotation
start) is turned on,
counting starts
from 0 and a
command current
position to the
target position is
displayed.
When a stop, a
point table
command position
is displayed for the
point table method
and 0 is always
displayed for the
program method.
Manual
"0" is always
displayed.
This digit will be disabled when [degree] of "Position data unit" is set in [Pr. PT01].
Additionally, setting "2" or more will be "positioning display".
_ x _ _ For manufacturer setting 0h
x _ _ _ Mark detection function selection
0: Current position latch function
1: Interrupt positioning function
0h