7. PARAMETERS 
7 -  66 
 
No./symbol/ 
name 
Setting 
digit 
Function 
Initial 
value 
[unit] 
Control 
mode 
CP CL 
PT29 
*TOP3 
Function 
selection T-3 
Set a polarity of DOG, SIG, PI1, PI2, and PI3.       
_ _ _ x 
(HEX) 
_ _ _ x (BIN): DOG (Proximity dog) polarity selection 
0: Dog detection with off 
1: Dog detection with on 
0h 
   
_ _ x _ (BIN): For manufacturer setting       
_ x _ _ (BIN): For manufacturer setting       
x _ _ _ (BIN): Mark detection input polarity 
Select MSD (Mark detection) input polarity. 
0: Normally closed contact 
1: Normally open contact 
 
   
  _ _ x _ 
(HEX) 
_ _ _ x (BIN): PI1 (Program input 1) polarity selection 
0: Positive logic 
1: Negative logic 
0h  
 
_ _ x _ (BIN): PI2 (Program input 2) polarity selection 
0: Positive logic 
1: Negative logic 
 
 
_ x _ _ (BIN): PI3 (Program input 3) polarity selection 
0: Positive logic 
1: Negative logic 
 
 
x _ _ _ (BIN): For manufacturer setting       
  _ x _ _  For manufacturer setting  0h     
  x _ _ _  For manufacturer setting  0h     
  Convert the setting value into hexadecimal as follows. 
0
Initial value
BIN HEX
Setting
0
0
00
0
0
DOG (Proximity dog) polarity selection
0
Initial value
BIN HEX
Setting
0
0
0
0
PI1 (Program input 1) polarity selection
PI2 (Program input 2) polarity selection
PI3 (Program input 3) polarity selection
Mark detection input polarity