10 - 15
10. OTHER FUNCTIONS
10.6.2 Remote STEP-RUN
Remote STEP-RUN refers to the function whereby the step run of the QnACPU is
performed from GPP function while the RUN/STOP key switch of the module is in RUN
position.
"Step run" is program execution that operates by one step at a time, starting from the
designated step.
For details on step run, refer to Section 8.7.
(1) Application of remote STEP-RUN
When debugging the system, for example, the program can be performed while
checking its execution and the contents of each device.
(2) Method for performing remote STEP-RUN
The procedure for remote STEP-RUN is as follows.
1) Set the RUN/STOP key switch of the CPU module to RUN position.
2) Perform STEP-RUN operation with GPP function.