EasyManua.ls Logo

Mobatime DTS 4802.masterclock - Impulse Line Output Specifications; DCF Active Line Output Specifications; RS 485 Line Output Specifications; DCF; Pulse Output Specifications

Default Icon
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© MOBATIME 113 / 120 800652.11
Impulse line output Alternatively to the MOBALine clock line or DCF active line
DTS 4801.masterclock: 1 line
DTS 4802.masterclock: 2 lines: max. current = sum of both lines
Current: up to 1000 mA impulse current (total)
Voltage: 24 VDC (polarized) (depending on power supply)
Line modes: 1 min., ½ -min., 1/5-min., 1/8-min., 1 sec
Impulse length: 200 – 30'000 ms, approx. 50 ms resolution
Pause length: 200 – 30'000 ms, approx. 50 ms resolution
Acceleration modes: 12 h, 24 h, 1 week
Max. time deviation against internal time: +/- 1 ms
At least 23.5 VDC power supply required
DCF active line Alternatively to the MOBALine clock line or impusle clock line
DTS 4801.masterclock: 1 line
DTS 4802.masterclock: 2 lines: max. current = sum of both lines
Current: up to 1000 mA impulse current (total)
Voltage: 24 VDC (polarized) (depending on power supply)
Line modes: See diagramm in chapter 6.5.5.
Max. time deviation (pulse start) against internal time: +/- 1 ms
At least 23.5 VDC power supply required
IRIG-B output (option) With built in IF 488 interface. The line has to be run in MOBALine mode.
(Only DTS 4801 IRIG-B: Art. Nr.: 203495).
Impedance: 600
Voltage: Amplitude 2 Vp-p
Max. time deviation against internal time: +/- 15 ms, jitter < 10 ms
RS 485 line output (Only DTS 4801). Alternatively to serial telegrams
Number of monitored clocks: max. 31
Max. time deviation against internal time: +/- 10 ms, jitter < 10 ms
Communication RS485, 19200, 8, n, 1, no flow control,
MOBA-RS485-protocol
DCF / pulse output DCF time code or pulse output selectable.
Passive current loop
Umax = 30 VDC, I
on
= 10..15 mA, I
off
< 1 mA @20VDC
Cable length max. 30 m (not in the 3 m range of a catenary wire (railway)).
DCF output: time zone selectable
Pulse mode: second, minute, hour,
user defined interval: 1-3600sec.
Pulse length: 20 – 500 ms, jitter pulse length: +/- 2 ms
Max. time deviation against internal time: +/- 1 ms,
jitter first pulse edge < 0.5 ms
Alarm contact Opening relay contact (alarm active contact open).
Switching load: 30 W (60 VDC or 1 A)
or 60 VA (30 VAC or 1 A)
Alarm reporting / Alarm contact see Alarm contact
Error messages E-Mail see E-Mail
SNMP-Notification see SNMP-Trap
Display see Display
Alarm LED -
Display 2 lines with up to 16 characters for the display of status information.
DC power supply 24 - 28 VDC / 1.5 A (28 V required for MOBALine)
Mains power supply 90 – 240 VAC / 50 - 60 Hz / max. 30 VA
Typical: < 5 VA @ 230 VAC (without external load)
Power supply output Nominal 28 VDC, max. 400 mA

Table of Contents