EasyManua.ls Logo

Mocom B CLASSIC - Page 76

Default Icon
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74
EN
B CLASSIC / B FUTURA / S CLASSIC - TECHNICAL MANUAL
SERVICE MENU
MENU SERVICE – RESET SERVICE
SQ39
This menu allows resetting the maintenance/service warning messages
in advance, compared to the foreseen number of cycles, if a maintenance
operation is performed before reaching the set limit that makes the
message appear.
Select SERVICE RESET to display four counters, with values expressed in
cycle number, corresponding to the following maintenance operations:
- Boiler lter/closing system lubrication
- Bacteriological lter replacement/Cleaning of tank and dust lters
- Boiler gasket replacement
- General service
By selecting RESET for one of the elements, a warning message
concerning the possible maintenance will be displayed.
If necessary, it is possible to select “Done” in order to reset the counter.
Otherwise, select “Remind” to keep the performed cycles count.
MENU SERVICE – SAFETY VALVE TEST
SQ40
Select this option to test the safety valve through steam pressurisation.
To start this test it is necessary to enter a dedicated password that must be
requested to the Manufacturer.

Related product manuals