85
EN
TECHNICAL MANUAL - B CLASSIC / B FUTURA / S CLASSIC
TECHNICAL DATASHEET
MEASUREMENT OF WORMSCREW POSITION
Measure the specied value as follows:
- Access the SERVICE menu > password 0829
- Select COMPONENT TEST > DOOR
- Close and lock the door (ref.SQ10)
- Measure the 5.3mm value (+/-0.5mm)
If the measured value is outside the allowed range, adjust the door.
ADJUSTING THE DOOR
Detach the plastic door cover from the cross member-door assembly, after removing the steel connection plate A;
pay attention to the 2 pushers and their springs B.
With the door open, loosen the retaining screw 1, which can be accessed from inside the cross member on hinge side,
and release the central round support of the door.
Adjust door position by working on the central round support 2 (using a suitable screwdriver) as follows:
- Turn clockwise to bring the door closer to the chamber and increase the measurement.
- Turn anticlockwise to bring the door closer to the cross member and decrease the measurement. Note: ¼ of a turn
of the central support will increase/decrease the measurement by 0.75mm.
- Lock the door support using the retaining screw 1.
- Measure wormscrew position again.
When the door is adjusted at the factory, it is placed in contact with the cross member and then:
- For 17/22 L models, the central round support is turned clockwise through 2 turns.
- For 28 L models, the central round support is turned clockwise through 3 turns.